High waterproof outdoor charger series
Products Display
Technical Parameters | |||
Model |
TTKC60KW~100KW |
TTEV120KW~240KW |
TTEV280KW~360KW |
System Input Characteristics | |||
Ac Input Voltage |
380Vac/400Vac/480Vac |
||
Power Supply |
Three-phase five-wire(3P+N+PE) |
||
power system |
TN-S |
||
Ac Network Frequency (HZ) |
50~60Hz |
||
Stand-by Power Consumption |
≤50W |
||
Leakage Current |
<3.5mA |
||
Start-Up Inrush Current |
Less than 10% of the rated input current |
||
System Output Characteristics |
|
||
Output Voltage |
150Vdc~1000Vdc |
||
Output Current Range |
5A~250A |
||
Output Power (kW) |
60KW~100KW |
120KW~240KW |
280KW~360KW |
Voltage Regulation Accuracy |
≤±0.5% |
||
Current Regulation Accuracy |
≤±1% |
||
Voltage Ripple |
≤±1% |
||
Efficiency |
≥93% |
||
Overload Capacity |
110% of rated power |
||
Communication Interfaces |
RS485 interface、CAN interface |
||
Protection Functions |
|
||
Battery Reverse Polarity Protection |
Yes |
||
Output Short Circuit Protection |
Yes |
||
Output Overvoltage/Overcurrent Protection |
Yes |
||
Overtemperature Protection |
Output shuts down if internal temperature >65℃ |
||
Abnormal Protection |
Shuts down with no output if power device anomaly occurs |
||
Other Parameters |
|
||
Protection Level |
IP54 |
||
Overvoltage Category |
OVC III |
||
Operating Temperature |
-20℃ to +65℃ (derated output from 45-65℃) |
||
Storage Temperature |
-40℃~+75℃ |
||
Relative Humidity |
5~95%, non-condensing |
||
Altitude |
Full load output up to 2000m |
||
Charger Dimensions |
740*400*1550mm (L*W*H) |
700*550*1800mm (L*W*H) |
1200*800*2000mm (L*W*H) |
Product Weight |
|
|
|
Cooling Method |
Air cooling |
Forklifts and Material Handling Equipment;Renewable Energy Storage Systems;Telecommunication and Data Centers